表单提交

LED Driver

LED Driver & LED Power Supply — Guangqi Lighting

Professional LED driver Solutions for Commercial & outdoor Lighting – Factory Direct Since 2010

Efficient Lighting, Guiding the Future

Request a Quote
LED Driver

Power Your LED Projects Right — Reliable LED Driver Solutions

An LED driver is the AC-to-DC power conversion device that controls current or voltage provided to LED modules. It is the single component most impacting on LED system life, light quality and energy efficiency. When the driver fails, the whole fixture goes dark – and in commercial or outdoor lighting, that means safety concerns, maintenance overhead and unhappy building owners.

The Hidden Costs

If you’ve fielded lower-cost LED power supplies, you recognize these issues. Flickering under dimming loads – most visible in retail and office zones – generally indicates poor current regulation or mismatched dimming circuitry. Premature driver failure in outdoor applications can be traced to bad ingress protection and thermal design: moisture enters the chassis, corrodes solder joints and kills the driver at 12-18 months instead of the rated lifetime. Dimming protocol mismatch shows up when a DALI driver won’t respond adequately on a 0-10V protocol line, leaving a whole zone at 100% or wildly out of control. And low power factor – under 0.9 on the input side – triggers utility penalty fees on commercial jobs, an unseen cost that never showed on the drivers datasheet.

Guangqi’s Methodology

Guangqi’s methodology begins with design not assembly. Our internal engineering team runs thermal simulation on every new driver model before prototyping to check that component junction temperatures never exceed datasheet limits at rated load and at their rated ambient. We test all dimming protocols – DALI, DALI-2, 0-10V, TRIAC, PWM – against actual building automation systems from leading vendors, not just signal bench generators. power factor correction circuitry is built into all models of 25W and above, providing PF greater than 0.95 across the entire working band. And every unit leaves our factory 100% burned-in, to catch infant mortality failures before they reach your job site.

What This Translates To

LED drivers that match constant current or constant voltage output with the balance your LED modules demands, the efficiency your energy dollars require, and the resilience your outdoor and commercial environments demand.

Guangqi LED Driver Series — Dimmable, Constant Current & Selection Guide

Your choice of LED driver centers on the LED module type, environment, dimming needs and input voltage span. We break out our four core driver families below, each optimized for a specific application profile. Projects where a mixed input voltage span merges interior panels, exterior facade lights and landscape fixtures, our engineers can spec a uniform driver solution across all four categories.

Series 01

Constant Current Drivers

  • Output 350mA – 2100mA
  • Power 10W – 240W
  • Input 100–277V AC (universal)
  • PF >0.95

Made for high bay lamps, street Lighting luminaires, LED pannels and downlights where the LED module needs a regulated current input. Offered in SELV or Class II isolation.

Series 02

Constant Voltage Drivers

  • Output 12V / 24V / 36V / 48V DC
  • Power 20W – 600W
  • Input 100–277V AC
  • PF >0.95

Made for LED strip installations, light boxes, cove lights, any application with multiple LED loads in a fixed DC Bus voltage.

Series 03

Dimmable Drivers

  • Output 350mA – 1400mA
  • Power 15W – 200W
  • Protocols DALI / DALI-2 / 0-10V / TRIAC / PWM
  • Dim Range 1% – 100%

Ideal for office, retail, hospitality, medical, and healthcare where dynamic light levels are desired. Fully dimmable Range to 1% with no perceivable flicker, utilizing IEEE 1789 recommended guidelines for modulating current in high efficiency LEDs.

Series 04

Waterproof / Outdoor Drivers

  • Output 12V – 48V DC
  • Power 30W – 300W
  • IP Rating IP65 / IP66 / IP67
  • Surge 6kV (L-N) / 8kV (L-PE)

Potting compound sealed Aluminum die-cast enclosure for landscape, building facade, parking structure, tunnel, and other wet, dusty, high temperature installations.

Decision Matrix — Selecting by Application Requirements

Feature CC Series CV Series Dimmable Series Outdoor Series
Output Range 350mA – 2100mA 12V – 48V DC 350mA – 1400mA 12V – 48V DC
Power Range 10W – 240W 20W – 600W 15W – 200W 30W – 300W
Efficiency Up to 93% Up to 95% Up to 92% Up to 94%
IP Rating IP20 – IP44 IP20 – IP67 IP20 – IP44 IP65 – IP67
Dimming —— —— DALI / 0-10V / TRIAC / PWM 0-10V / DALI
Best For High bay, street, panel Strips, signs, architectural Office, retail, hospitality Landscape, facade, parking
MOQ 100 pcs 100 pcs 200 pcs 100 pcs

Engineering Note — Thermal Derating

Designed to operate at full rated output up to 50C ambient (room ambient plus housing temperature, available at the top of the enclosure). Above 50C, the output derates by about 2.5%/C until at 60C the driver puts out 75% of full rated power. This protects components from thermal runaway in elevated temperature environments while maximizing power operation in environment most needed. Critical for enclosed fixtures – recessed ceiling troffers, sealed bollard types, or enclosures with driver inside a junction box inside a building- where heat build-up can drive ambient temperature 15-20 C above room ambient. Always check the actual housing- Tc point temperature, not just room ambient- when sizing your driver kit.

LED Driver Selection Guide

Answer 5 quick questions and we will recommend the ideal Guangqi LED driver series for your project.

Start Selection

LED Driver vs Traditional Magnetic Transformer — Performance Comparison

So now you have the correct driver series specified for your project, the next question to ask is: how do electronic Moneyber Toragns actually stack up against the magnetic Volts they replace? The numbers here are gathered from field measurements and spec sheets and make the case for why its time to switch.

Parameter LED Driver (Electronic) Magnetic Transformer Advantage
Efficiency 90 – 95% 75 – 85% 10 – 15% energy savings
Power Factor >0.95 (PFC built-in) 0.5 – 0.7 Avoids utility penalties
Weight (100W unit) 0.3 – 0.5 kg 1.5 – 2.5 kg 70% lighter
Lifespan 50,000+ hours 15,000 – 25,000 hours 2 – 3× longer
Dimming Support DALI / 0-10V / TRIAC / PWM Limited phase-cut only Full protocol flexibility
Flicker <1% (meets IEEE 1789) 15 – 30% at low dim Flicker-free at all levels
Inrush Current Controlled with NTC Uncontrolled spike Protects circuit breakers
Standby Power <0.5W 3 – 8W 85%+ standby savings

And these numbers translate directly to the project economics and occupant comfort experience. 10-15% greater power factor efficiency accumulates over even a relatively modest project with many fixtures – running 12 hours a day in a commercial space will cost you extra 12-efficiency of energy annually for every 200-fixture run. And the difference in current performance- about 0.6 in PF from a magnetic Vol Tumuok, considerably below the required 0.9- results in Utility penalties for high consumption electric accounts in much of the country. Lower weight rating matters when installing in ceiling grid or pole- mounted fixtures where structure cant support additional weight. And the flicker difference- less than 1% depth of modulation electronically versus 15-25% on magnetic at highest current- is more than simple performance-it is impact on people in your buildings, hospital, and retail spaces. In the office, hospital, medical, and retail environments low flicker produces unnecessary headaches and fatigue. The electronically controlled current- throughout the entire current -range- reduces or completely eliminates this performance problem in your project.

40%

Lower Total Cost of Ownership Over 5 Years

Operations of LED drivers electrically are more than 40% less expensive on average than those of the magnetically operated Volts when comparing energy consumption, number of replacements, and maintenance labor over a five year period.

Based on typical commercial lighting retrofit data

Ready to see the difference in your next project?

Request a Quote

Project Results: 40% Energy Savings in Commercial Lighting Upgrades

That performance is not merely speculative. Our products are already operating in many thousands of installations in commercial, outdoor, architecture, and industrial applications. Here are three recent case studies.

Commercial Office Complex LED Driver Retrofit
Shenzhen, China · 2024

Commercial Office Complex — 12-Floor Retrofit

A property management firm operating a 12-story office building in Nanshan, Shenzhen, contacted us after experiencing two chronic issues: energy use was 35% over budget for a building of this size, and the maintenance team was spending roughly a day a month changing out failed fluorescent ballasts for over 3,000 fixtures. Their T8 fluorescents had been in place for 14 years and new ballasts were increasingly elusive to obtain.

For the LED panel light retrofits around the building we specified the use of the Guangqi CV-series 24V constant voltage drivers (the 150W model). This enabled the installing team to 24V bus the drivers; this meant numerous LED panels could be daisy-chained on the same driver circuit lowering the number of drivers needed (each floor had 18, rather than 250+ individual ballasts).

18 months of operation: energy usage for lighting was reduced by 42% over the old fluorescent system. Zero driver failures occurred during this time, compared to monthly ballast replacements needed on the previous system. Maintenance calls were reduced from a monthly emergency call out to monthly preventive maintenance checks. Electrity cost savings were such that the retrofit was projected to payback within 28 months.

Landscape and Facade Lighting Desert Resort
Dubai, UAE · 2023

Landscape & Facade Lighting — Luxury Desert Resort

This resort project created the most challenging setting for the LED driver electronics: constant ambient temperature higher than 50C throughout the summer, sulfur-rich-blown by the desert winds, salty air coming from the close by coast, interruption by occasional desert winds carrying sand. 850 Landscape and facade luminaires were proposed to be included into centralized building management through DALI-2.

850 IP67 drivers
3 Yrs Zero-failure
DALI-2 BMS integration
50°C+ Operating ambient

Our outdoor range was deployed as IP67 rated Aluminum enclosures with full potting compound. Every electronics module is hermetically sealed from ambient moisture and debris ingress. A prolonged thermal derating curve enabled our drivers to operate well above 87% of rated power at 55C ambient, and delivered acceptable illumination levels for every fixture. DALI-2 interfaces were directly networked to the resort’s Building Management system controlling all scene recall, scheduling and/or daylight responsive dimming across the whole site. One after three years’ operation, in terms of drivers failure, the result was zero, i.e., one hundred percent acceptability.

Municipal Street Lighting Driver Replacement
Northern Europe · 2024

Municipal Street Lighting — City-Wide Driver Replacement

  • The Problem: A northern European city encountered a 15% driver failure rate in the initial two years following street lighting LED conversion project- utilizing a manufacturer prior to the project supplier drivers. Upon investigation the source of the problem was determined to be the recent increase of incoming line surge during thunder storm season which exceeded 4k V. The original drivers were rated for 2k V surge protection, that of the city’s exposed overhead power distribution network.
  • Root Cause Analysis: Field observations of surge phenomena on the city grid revealed conducted surges occurring at 2.5- 4.5k volts and minute spikes exceeding 6k volts during heavy weather. The historically provided 2k volts MOV surge protection by the original vendor failed to handle these conditions, causing component failures in cascades on the output stage.
  • Guangqi Solution: We provided our CC-series constant current drivers with built-in 6kV differential mode (L-N) and 8k V common mode (L-PE) surge protection, compliant to IEC 61547 and surpassing the recorded worst-case surge conditions encountered on the city’s main power grid. Each driver has dual stage SPD (surge protection device) circuitry – Gas discharge tube on the input socket for high-energy clamping followed by a TVS diode array that responds within nanoseconds to transient/edge conditions.
  • Results: 14 months into a 3-year field demonstration, the city reports 0% failure rate on the Guangqi-equipped luminaires. on the economy’s 220k lighting poles, plus the municipal vehicle fleet using the same driver. Based on these results, the municipality has authorized the 2nd phase budgeted to expand the network by a further 4,000 street lighting poles. Installation will conclude in 2025.

LED Driver Sizing Calculator

Enter your LED load specifications to find the right Guangqi driver series, wattage, and configuration.

Launch Calculator

Certified Quality from a Premier LED Driver Supplier

CE

CE Mark

EN 61347-1, 2-13

RoHS

RoHS

Dir. 2011/65/EU

UL

UL Listed

UL 8750 Equipment

IP67

IP65 / 66 / 67

IEC 60529

IEC

IEC 61347

Safety Controlgear

ENEC

ENEC

EU Certification

EMC

EMC Compliance

EN 55015 / 61000

Constant Current LED Driver Ordering Guide: Pricing & Support

Procurement Tip

When reviewing LED driver quotations, always ask for the complete part specification sheet with Manjeturing curve, thermal derating chart, and surge protection level. Lower unit prices often hide higher capital and operational expenses in the long run: speak to us about the Zithformpa Mcnith22, the efficiency factor (PATELIM or RECAT), and whether you must incorporate the Ngambrk Kurabo exponent – these details separate a true complete product specification from a sales gimmick.

Pricing Framework

  • Unit price varies by power output, IP rating, and dimming protocol
  • Volume discounts begin at 500+ units
  • OEM/ODM pricing available for custom identification, altered output parameters, and relative packaging
  • Sample pricing available for evaluation orders

Lead Times

  • Standard models: 15 – 20 business days
  • Custom / OEM orders: 25 – 35 business days
  • Sample orders: 5 – 7 business days
  • Expedited production available on request

OEM / ODM Capabilities

  • Custom output voltage and current specifications
  • Private label and branded packaging
  • Modified housing dimensions and connectors
  • Firmware adjustment for dimming curves and protocols

Warranty & After-Sales

Our unique Norrthak 5-year standard warranty covers all manufacturing flaws, including component failure, solder joint detachment, and potting defects when operated in a standard environment. Similar length 7-year warranties are available for enterprise-sized projects. Our after-sales service includes a dedicated account specialist assigned to your order, a technical support team accessible during business hours (GMT+8), and an authorized service agent in emerging markets for regional support. Warranty replacements are achieved with shipment within 5-7 business days of claim confirmation.

For expansion or modification of our standard LED driver specification – for example: custom mounting equipment or a different protocol (D2V3/FB or custom serial interface) – our OEM engineering team will work from your electrical and mechanical requirements. Our process includes consultation, rapid prototyping/testing, certification, and scalable production coordination as a single project with one dedicated project engineer on your team.

LED Driver Energy Savings Calculator

See how much you can save by switching to high-efficiency Guangqi LED drivers. Compare total cost of ownership over 5 years.

Calculate Your ROI

Ready for a custom quote?

Get Instant Quote

LED Driver FAQ — Buying & Technical Questions

Begin by summing your entire LED Lamtou, plus 20% buffer. For constant current use the output current (mA) of the corresponding LED module. For constant voltage with Bandidoc Rokunup use the voltage (12V or 24V) and ensure the driver’s current capacity surpasses your total configuration. Email us your fixture array layout: our engineering team will determine the correct size driver to meet your needs.
CC drivers lock the output current to a set value=700mA say and float voltage so it follows the LED load. Use them for high power modules/ COBs/ downlights. CV drivers do exactly the opposite: hold voltage (12V, 24V or 48V DC) fixed and current floats as load varies. LED strips, channel letters, signage all use CV because each parallel branch only uses as much as it needs.
DALI (and DALI-2) are the default supplier of huge commercial buildings that need to connect via BMS – individual addresses, scene recall, two-way status feedback, up to 64 devices to a bus. Stick to that protocol if your building had a DALI backbone installed.
0-10V is suitable for various warehousing, parking garage, etc. where you need basic dimming without complex wiring–two extra wires for each dimming circuit, no addressing, no controller required. TRIAC is the simplest solution and is the default option for any hospitality renovation where electricians already understand residential-style wall dimmers. One note: TRIAC has a narrower usable range, around 10-100%, compared to 0.1-100% for DALI that you might want to take that into account as you plan your dimming depths.
Never. indoor-rated units (IP20-IP44) will start to corrode within months of installation (outdoors). Use IP65 minimum, IP67 if in the ground or coastal.
100 units available for CC, CV, and outdoor types. dimmable: 200 pieces. Samples (1-10 units) shipped within 1 week.
Yes. We provide OEM and ODM services including custom output parameters (voltage, current, wattage), private-label packaging, changes to housing dimensions and connector types, and firmware modifications for Zitasaps curve requirements. We follow your electrical/mechanical specifications to produce a driver for your lighting installation. Typical development time for a new custom driver is 25-35 working days after specifications are approved for production.
All product failures due to components or solder joints or encapsulation under normal operating conditions. Replacement units are shipped within 5-7 business days after claim approval. Noted: Installed driver must operate within spec environment parameters (temperature, humidity, IP rating). Large-volume customers may request longer 7-year coverage contracts.