表单提交

Outdoor LED Flood Lights

Outdoor LED Flood Lights for Commercial & Industrial Use

High power LED floodlights for parking lots, stadiums, perimeter security, industrial sites 50W to 1000W. Waterproof IP65/IP66. Directs from the manufacturer – OEM capability

130+

Lm/W Efficacy

50,000

Hour Lifespan

IP66

Protection Rating

15+

Years Manufacturing

Outdoor LED Flood Lights for Industrial Sites

Outdoor LED Certifications and Specifications

  • CE

    Certified

  • RoHS

    Compliant

  • IP65

    Rated

  • IP66

    Available

  • CRI

    ≥ 80

  • 5000K

    / CCT Sel

What Are Outdoor LED Flood Lights?

An outdoor LED flood light is a high-intensity, wide-beam light fixture that uses light-emitting diode (LED) technology to deliver broad, uniform illumination across large exterior areas. Unlike a spotlight — which concentrates a narrow beam on a single point — LED floodlights spread light across a wide angle, standard 90°–120°, covering large surfaces uniformly. This makes them the go-to choice for exterior lighting of perimeters, parking lots, building facades, and open-air venues. Their high brightness output makes them equally suited to area lighting of sports fields, landscape lighting, and any large-area floodlighting application.

These light fixtures convert electrical power into light through semiconductor electroluminescence, achieving efficiencies of 120–150 lm/W — 3 to 5 times more efficient than the metal halide, high-pressure sodium, and high-intensity discharge (HID) sources they replace. This fundamental energy efficiency advantage, combined with a 50,000-hour rated lifespan per IEC 62717, makes waterproof LED flood lights the benchmark for modern commercial outdoor lighting. Compared to traditional HID sources, LED technology delivers superior lumen maintenance and contains no mercury — making them environmentally friendly for street lights, area lights, and large-area exterior illumination.

At Guangqi Lighting, our in-house team designs and manufactures these outdoor LED flood lights — maintaining full control across mold development, optics engineering, thermal management, and smart driver design. This vertical integration allows us to deliver consistent lumen maintenance and precise color temperature control across our full 50W–1000W range.

High Efficacy — 130+ lm/W

More light per watt than any legacy technology, reducing electricity costs by 60–80% vs. metal halide.

IP65 / IP66 Weatherproof

Sealed against dust ingress and pressurized water jets per IEC 60529 — built for outdoor spaces year-round.

Stable CCT — 5000K Daylight

Standard 5000K daylight output with selectable CCT options (3000K–6500K) for specific application needs.

50,000-Hour Service Life

Rated to L70 standard — maintaining 70% of initial lumen output at end of rated life, slashing maintenance costs.

Parameter LED Flood Light Metal Halide
Efficacy 130+ lm/W 75–100 lm/W
Lifespan 50,000 h 10,000–15,000 h
Warm-up Time Instant (0s) 3–5 minutes
Mercury Content None — RoHS Contains mercury
CRI ≥ 80 (up to 90) 60–75
Dimming 0–100% DALI Not practical
Maintenance Minimal Frequent relamping

LED Flood Light Wattage Guide: 50W to 1000W

Typically, the most common question that representatives of facilities and contractors ask us is about the wattage required in their situation. There are three primary aspects – the size of the space, the mounting height and the illumination level (foot-candles or lux). Use the following table to help choose a suitable LED fixture for your needs.

50W LED Flood Light

50 Watts

— 6,500 lm
Entry Commercial
6,500 lm output
90°–120° beam angle
IP65 standard
Mount height: 4–6 m
Coverage: ~50–80 m²
Building facades · Signage · Garden perimeter
100W LED Flood Light

100 Watts

— 13,000 lm
Standard Commercial
13,000 lm output
Adjustable yoke/knuckle mount
IP65 / IP66 selectable
Mount height: 6–10 m
Coverage: ~150–250 m²
Parking lots · Warehouse exteriors · Security perimeters
200W LED Flood Light

200 Watts

— 26,000 lm
Medium Commercial
26,000 lm output
5000K / CCT selectable
IP66 rated
Mount height: 8–14 m
Coverage: ~350–500 m²
Large parking lots · Loading docks · Sports perimeters
400W LED Flood Light

400 Watts

— 52,000 lm
Heavy Commercial
52,000 lm output
Precision optic modules
IP66 standard
Mount height: 12–20 m
Coverage: ~800–1,200 m²
Stadium perimeters · Ports · Large construction sites
1000W LED Flood Light

1000 Watts

— 130,000 lm
Industrial / Stadium
130,000 lm output
High-mast pole mount
IP66 · DALI dimming
Mount height: 20–40 m
Coverage: ~3,000+ m²
Sports fields · Airports · Industrial complexes · Ports

Practical Rule of Thumb:

In parking lot floodlighting, IES RP-20 proposes a maintained horizontal level of 1 to 3 foot-candles (10-33 lux) for open parking areas and 3 to 5 foot-candles for covered/enclosed parking facilities. For the typical 8-10 m mounting heights with 100W (13,000 lm) floodlights, the illumination pattern covers 200 m at 2 fc. This provides a useful point to begin a photometric analysis. It is typical among most contractors that working one wattage level higher than their first assessment compensates for the real-world derating factors of heat and fixture age. [INDUSTRY-STD: IES RP-20-14, Recommended Practice for Parking Facilities Lighting]

LED Flood Light Applications: Parking Lots, Stadiums & Perimeter Security

Commercial and industrial outdoor LED flood lights are central to exterior illumination in every field of use. Each application carries distinct illuminance requirements, mounting constraints, and environmental exposure conditions.

Parking Lot Lighting

Parking Lot Lighting

LED lights for parking lots must deliver uniform illumination across large, open areas to aid motorists in wayfinding and ensure pedestrian safety. Per IES RP-20, maintained illuminance for open surface lots is 1–3 fc (10–32 lux). A 100W area light with a 130° beam angle, mounted at 8–10 m, typically covers one standard parking bay row. Dusk to dawn photodetector control reduces daily operating hours, improving visibility and safety while extending fixture lifespan.

Recommended Wattage100–200W
IP RatingIP65 min.
Perimeter Security Lighting

Perimeter Security Lighting

Outdoor security flood lights serve a dual purpose: deterrence and detection. Well-illuminated perimeters consistently reduce opportunistic incidents by improving camera visibility and eliminating shadow zones. A CCT of 5000K–6500K is recommended for security applications — cooler light improves contrast for CCTV capture and is more alerting for security personnel during night shifts.

Recommended Wattage50–150W
CCT Preference5000K–6500K
Stadium & Sports Field Lighting

Stadium & Sports Field Lighting

Stadium lights demand extreme precision: uniform light distribution (U1 ≥ 0.5 per EN 12193), minimal glare (GR ≤ 50), and high CRI (≥ 80, preferably ≥ 90 for HDTV broadcast). At 20–40 m mounting heights, 400W–1000W fixtures are standard. Multiple fixtures per pole create the overlapping beam patterns required to eliminate shadow zones on the playing surface.

Recommended Wattage400–1000W
CRI Requirement≥ 80 (90 for broadcast)
Warehouse & Industrial Exterior

Warehouse & Industrial Exterior

Loading docks and warehouse perimeters require rugged fixtures that withstand high-pressure hose-down cleaning, chemical exposure, and continuous operation. IP66 is the standard specification here. Die-cast aluminium housings with corrosion-resistant finishes and sealed optical chambers are essential. We address potential failure points with double-sealed gland fittings on all IP66 models.

Recommended Wattage100–300W
IP Rating RequiredIP66
Building Facade & Architectural

Building Facade & Architectural

Facade illumination requires adjustable beam angles and precise aiming achieved through yoke or knuckle mount systems. Warmer CCTs (3000K–4000K) are typically specified for hospitality; cooler 5000K is preferred for corporate facades. RGB and tunable white options are available for special event illumination, aiming upward from ground level or downward from parapets.

Recommended Wattage50–200W
CCT Range3000K–6500K
Ports, Airports & Infrastructure

Ports, Airports & Infrastructure

Marine port applications pose the greatest outdoor environment adversities: salt atmosphere, high vibration, and corrosion. Use of stainless steel hardware and marine-grade aluminium housing is required. For aviation safety, obstructions must follow FAA circulars. Our Guangqi series is ideal for extreme ambient temperatures (up to 45°C) in infrastructure projects.

Recommended Wattage200–1000W
Special RequirementIP66 + marine grade

Technical Specifications of Commercial Outdoor LED Flood Lights

Commercial LED flood lights need careful specification for flood lighting to be effective: too little output and the space is unsafe or non-compliant; too much and the result is over-lit and wasteful. The table below summarizes our standard commercial & industrial LED flood light range, covering durability ratings, lumen output, and IP classification across all wattages.

Parameter 50W 100W 200W 400W 1000W Notes
Lumen Output 6,500 lm 13,000 lm 26,000 lm 52,000 lm 130,000 lm At 25°C ambient, initial lumen values
Efficacy 130 lm/W (typical) — 150 lm/W (high-efficiency models) [USER-DATA] Guangqi Lighting spec
CCT Options 3000K · 4000K · 5000K · 6500K 5000K standard; selectable CCT on 100W–400W
CRI ≥ 80 standard · ≥ 90 available on request CRI ≥ 90 for broadcast/sports
IP Rating IP65 IP65 / IP66 IP66 IP66 IP66 Per IEC 60529
Beam Angle 60° · 90° · 120° · Custom optics available Adjustable yoke/knuckle mount ±180°
Operating Temp. −40°C to +50°C Die-cast aluminium with integrated heat sink
Input Voltage AC 100–277V (standard) · AC 347–480V (available) Universal voltage driver
Power Factor > 0.95 High PF driver reduces reactive load
Photocell Optional dusk-to-dawn photocell · NEMA 5-pin socket available Automatic on/off; dusk threshold adjustable
Dimming 0–10V · DALI · Triac (model dependent) DALI standard on 200W–1000W
Housing Die-cast aluminium (ADC12) — anodized or powder-coated Salt-spray tested 1,000h per IEC 60068-2-11
Lifespan (L70) 50,000 hours Per IEC 62717 — 17 years at 8h/day
Warranty 2 years full replacement Guangqi Lighting global warranty
×
Zoomed Factory Image

Outdoor LED Security Light Quality Certifications & Compliance Standards

For commercial & industrial LED flood light purchase, certification is not simply a nice-to-have – it is your legal proof that the fixture conforms to the specified performance levels, and is safe for use in your territory. Guangqi Lighting now have the following standards conformance on our outdoor flood light range:

CE

CE Mark

Mandatory for sale in the European Economic Area. Confirms compliance with EU directives including EN 60598-1 (luminaires), EN 61000 (EMC), and EN 62471 (photobiological safety). All Guangqi Lighting outdoor flood lights carry the CE mark.

RoHS

RoHS Compliant

Restriction of Hazardous Substances Directive (2011/65/EU). Confirms absence of mercury, lead, cadmium, hexavalent chromium, and other restricted substances. Our LED fixtures contain zero mercury — unlike the metal halide, HPS, and incandescent light bulb technologies they replace — making them the environmentally responsible electric light source for wall-mounted, pole-mounted, and structural installations.

IP65

IP65 — Weatherproof

Per IEC 60529. Provides complete protection against solid particles (dust-tight) and protection against low-pressure water jets from any direction. Waterproofing at IP65 level is suitable for all standard outdoor environments, including rain, snow, and car wash proximity — ensuring the fixture’s electrical components remain sealed.

IP66

IP66 — Heavy-Duty Waterproof

Per IEC 60529. Adds protection against high-pressure water jets. Required for port areas, marine environments, loading docks, industrial facilities with wash-down procedures, and any application where the fixture may be directly hosed down.

CRI≥80

Color Rendering Index

A CRI of ≥ 80 ensures that colors under the flood light appear natural and accurate — critical for security (accurate color rendering for CCTV), retail facades, and sports venues where player/ball visibility matters. Our standard range achieves CRI ≥ 80; CRI ≥ 90 available on request.

IEC 62717

LED Module Lifespan

International standard governing LED module performance requirements and lifespan measurement methodology. Our 50,000-hour L70 lifespan claim is tested and reported per the LM-80 testing protocol, with TM-21 projection methodology applied for lifespan extrapolation.

Note for North American Procurement:

DLC (DesignLights Consortium) certification and UL listing is available on select models for users and distributors operating in US & Canada. Please specify when ordering. All Guangqi Lighting standard product line is CE-certified to meet ever-growing international and non-UL markets, while DLC certification may be issued on qualifying models on special request.

LED Flood Lights vs. Metal Halide: Energy Savings & ROI

The first question a facilities manager should be asking when choosing LED flood light upgrades is not “what is the up-front cost?” but “what is the ROI?” Modern LED technology delivers ROI to your balance sheet within 12-36 months in the form of greatly reduced energy, maintenance, and replacement costs. People and business processes also benefit from LED flood lights: high performance lighting is more environmentally and emotionally friendly, with no mercury, lower emissions, and less waste. Compared with old-fashioned metal halide lights, energy-efficient LED flood lights will save your business 60-80% on its electricity supply.

78%
Typical energy reduction — LED vs. equivalent metal halide output
Comparison Factor LED 100W Metal Halide 400W
Light Output 13,000 lm 13,500 lm
Power Draw 100 W 400 W + ballast (~450W)
Efficacy 130 lm/W 30 lm/W (effective)
Annual Energy (8h/day) 292 kWh 1,314 kWh
Annual Energy Cost (@$0.12/kWh) $35 $158
Rated Lifespan 50,000 h 10,000–15,000 h
Replacements over 50,000h 0 3–4 relamping cycles
Maintenance Cost / 50,000h ~$0 $120–$200 per fixture
Warm-up / Restrike Time Instant 3–5 min / 5–10 min
Mercury Hazardous Waste None Disposal required
If 20 fixtures are installed in a car park, replacing 400W metal halide with 100W LED equivalents will cut electricity use by 24,440 kWh/year — saving approximately $2,930 annually at $0.12/kWh. Factor in an estimated $4,000 in maintenance savings over 5 years and the total 5-year saving exceeds $18,000 for a 20-fixture installation.

The 100W LED (13,000 lm) replaces a 400W metal halide that would produce the same accessible illumination at the specified surface – the LED’s greater lumen maintenance and more efficient predictability reduces the energy wasted in the light emitted in undirected directions with HID fixtures.

Based on [industry-STD] IEC 62717 life-span data and [Qualified] industry-average energy cost. Actual savings will vary depending on the site and usage patterns.

Common Mistake We See

Many purchasing decision-makers compare the wattage of LED fixtures to that of metal halide fixtures – this results in an erroneous calculation that implies a 400W LED improves on the metal halide equivalenant. No. The comparison should be in lumen generation: a 100W LED at 13,000 lm replaces a 400W metal halide at, at best, some 13,600 (74%) usable lumens. Demand your LED supplier supply you with photometric files (IES files) for both fixtures so that you can specify by on-surface (ie task) illuminance.

Commercial & Industrial LED Flood Light Projects

Three international projects outlining the subtle differences between requirements, specifications and results on an LED flood light installation.
Parking Lot — Southeast Asia

Shopping Complex Parking: 480-Space Open Lot, Malaysia

A 480-space open-air parking lot used 150W metal halide fixtures (average lamp life in harsh environment averaged 18 months before significant lumen depreciation was evident). Facility manager indicated 3-4 call backs per year per wing for lamp changes, dust cleaning, and ballast replacements. Guangqi Lighting supplied 96 units of our 100W LED flood light IP65 (5000K, knuckle) mounted to existing 8 meter poles, measured illuminance in lot averaged 2.3 fc, within IES RP-20 Class P2 performance requirements.
“The contractor finished the upgrade in 4 evenings, no impact on parking operation. Noticing a huge reduction in light variation across the lot- parking security team and taxi drivers say so as well.” Facilities Director, Kuala Lumpur Retail Group
76%
Energy Reduction
$0
Maintenance Calls, 24 Months
18 mo
Full Payback Period
96
Fixtures Installed
Industrial Exterior — Middle East

Port Container Terminal Perimeter: 3.2km Security Lighting, UAE

As part of a full perimeter security upgrade for a major container port in the United Arab Emirates, a specification was issued for complete perimeter fixtures, rated to withstand salt air, Ambient up to 48C, and Haz Mat wash-down from port cleaning trucks. Specification 10C-55C operating range, IP66, 5000K for CCTV. Guangqi Lighting installed 240 pieces of our 200W flood IP66 IP66 (12 m utility poles, 40 m spacing) perimeter lighting system, performed to within 3.1 fc of most uniformity across perimeter boundary, dusk-to-dawn photocell illumination control.
“Traffic needs to travel 40m to reach third light pole, so we need mass of light over entire perimeter. Specifying IP66 required for twice weekly power-wash-down. 30 months later, zero failures. Not a single field adjustment required.” Project Engineer, Port Infrastructure, Dubai
240
Fixtures (IP66)
3.2km
Perimeter Lit
48°C
Max Operating Temp.
5000K
CCTV-Optimized CCT
Sports Field — Europe

Municipal Athletics Track: 400m Standard Facility, Germany

A 400m running track for a German public works department was built with our LED flood lights to meet demanding DIN EN 12193 Class 3 specs for outdoor sport lighting (Eh,avg steady 75lux U1 0.35). 6 poles at 12m, each with 2 IP66 LED flood lights with 60 degree field angle optics (for precision illumination). DIALux appeal file provided to the facility architect prior to contract signing.
“As shown, the DIALux appeal code corresponded very accurately with our on-field results, 8% variance. Machine-building impact new to our procurement team to understand – but having the database visuals made the buying process simple.” Municipal Works Department, Baden-Württemberg
12
Fixtures (200W each)
95 lux
Measured Avg. Illuminance
0.42
Uniformity U1 Achieved
CE + RoHS
Compliance Required

Commercial & Industrial LED Flood Light Pricing Guide

Prices for high-quality LED flood lights vary considerably on wattage, IP grade, listing & certifications, quantity ordered. As a manufacturer, direct exporter, to contractors/distributors/buyers throughout the world – such as a major LED flood light buyer in the United States, to a local government buyer in the Netherlands, and a renewal project buyer in Taiwan – Guangqi Lighting does not have any distribution inflated pricing, and offers scaled prices for bulk buys. Below is a range of current ex-factory (USD) pricing for CE-approved standard broadcast-style sports flood lights.

Entry Range

50W–100W Standard
$35 – $95 / fixture (ex-works)
IP65 waterproof rating
5000K standard CCT
CE + RoHS certified
Knuckle or yoke mount
MOQ: 10 units
2-year warranty

Commercial Grade

150W–300W
$110 – $280 / fixture (ex-works)
IP65 or IP66 selectable
CCT selectable 3000K–6500K
CE + RoHS + optional DLC
Photocell option available
MOQ: 5 units
2-year warranty

Industrial Grade

400W–1000W
$320 – $950 / fixture (ex-works)
IP66 standard
DALI dimming standard
Custom optics available
High-mast bracket options
MOQ: 2 units
2-year warranty + extended options

What Affects Pricing?

IP Rating: IP66 adds 10–20% vs. IP65
CCT Selectability: Multi-CCT driver adds 8–12%
Certifications: DLC additional cost
Quantity: 50+ units typically reduce unit price 12–22%
Custom Color/Finish: Powder coat options add 5–8%
OEM Branding: Can do from 50 up (no additional charge)

OEM & Custom Solutions

Fully built for OEM private labeling and export to North American, European, and Southeast Asian markets. Custom wattage, beam angle, CCT, and color finish modifications — from prototype to mass production — are handled by a dedicated engineering team, typically within 4–6 weeks.
Get Instant Quote

Frequently Asked Questions (FAQs)

The main disadvantages are higher initial fixture cost versus a halogen or HPS fixture and heat output at the driver level (drivers shall not be enclosed in non-ventilated locations.) But in commercial use with 50,000 hours of life time and saving 60-80% energy, most to all of the job will amortize the premium in 18–36 months. The impression of a high upfront cost means is largely based on comparing the list price of LED fixtures to the fixture price of a metal halide fixture without adding in cost for the ballast of the metal halide as well as the relamping labor and disposal costs over the life of the fixture. (50,000 hours equates to fully amortizing the premium resulting in a lower LED price of about $10–15 per fixture.)